Configure and automate Home Assistant with Claude, ChatGPT, and other AI assistants.
AIxEnergy Map is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Remote MCP server for data-center siting, ISO queues, and grid and capital data.
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user --transport http aixenergy-map-mcp https://map.aixenergy.io/mcp --header 'Authorization: Bearer ${AUTHORIZATION}'
# 2 — ask your agent for something these tools do
# underwrite_large_load_asset, screen_regional_capacity, profile_counterparty and 14 more
It needs AUTHORIZATION (Bearer token. Use an AIxEnergy member token or a scoped API key that begins with aix_mcp_. Unauthenticated clients can list tools; calling tools may require…): this sends it in the Authorization header from your environment, so export it first — its endpoint answers 401 without it.
AIxEnergy Map costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. Nothing here runs on your machine and nothing runs on ours: this server answers at its publisher’s own address, and what you install is the connection straight to it.
This is a public server: it answers at its publisher’s own address and this marketplace is not in the path. Claude Code registers it in one command; --scope user makes it available in every project. The transport below is http, as the publisher's own manifest declares it. Claude Code reads AUTHORIZATION (Bearer token. Use an AIxEnergy member token or a scoped API key that begins with aix_mcp_. Unauthenticated clients can list tools; calling tools may require…) from your environment each time it connects and sends it in the Authorization header — its endpoint answers 401 without it — so the key stays out of its config: export it in your shell profile (macOS, Linux), or run setx AUTHORIZATION … and open a new terminal (Windows).
claude mcp add --scope user --transport http aixenergy-map-mcp https://map.aixenergy.io/mcp --header 'Authorization: Bearer ${AUTHORIZATION}'Reconnect, or start a new session, and the tools appear in the model’s tool list.
Nothing is required, but it can take Authorization header (Bearer token. Use an AIxEnergy member token or a scoped API key that begins with aix_mcp_. Unauthenticated clients can list tools; calling tools may require a token.) if you want to set it.
One config entry pointing straight at the publisher’s own address — this marketplace is not in the path, and nothing from this listing executes on your machine.
17 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Multi-domain diligence workflow synthesizing Physical Siting & GIS (Map), Interconnection Queue Status (Monitor), Capital Commitments & Delay Risk (Capital), Campus Nodal LMP Basis Analytics, and Apparatus Velocity. Returns substation MVA headroom, queue study stage, completion probability P(eventual), capital gap, capital at delay risk, and cryptographic SEC/docket evidence passages in a single t
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| canonical_project_id | string | no | — |
| project_id | string | no | — |
| queue_position_id | string | no | — |
| project_name | string | no | — |
| location | string | no | — |
| state | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| target_mw | number | no | — |
| power_factor | number | no | — |
| cooling_type | string | no | — |
| perspective | string | no | — |
| market | string | no | — |
| include_all_domains | boolean | no | — |
| include_nodal_basis | boolean | no | — |
| include_equipment_lead_times | boolean | no | — |
| include_pnode_bus | boolean | no | — |
| include_8760_profile | boolean | no | — |
| cooling_topology | string | no | — |
Evaluates whether a target market or county can support a large-load power profile (e.g. 500 MW). Analyzes available transmission substation headroom, radial line distance, competing large-load queue backlog, and active developer capital deployments.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| location | string | no | — |
| query | string | no | — |
| target_mw | number | no | — |
| max_radius_miles | number | no | — |
| radius_miles | number | no | — |
| required_voltage_kv | number | no | — |
| market | string | no | — |
| state | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
Comprehensive counterparty profile for developers, hyperscalers, lenders, and utilities. Aggregates campus footprints, operating vs pipeline MW, active ISO interconnection queue requests, and balance sheet capital deployments.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| company_name | string | no | — |
| organization_id | string | no | — |
| query | string | no | — |
| include_filings | boolean | no | — |
| include_projects | boolean | no | — |
| include_capital | boolean | no | — |
| include_campuses | boolean | no | — |
| include_queue_filings | boolean | no | — |
| include_capital_stack | boolean | no | — |
Propagates counterfactual physical grid, cluster queue MW, transformer lead-time, nodal LMP basis, and interest-rate shocks through a 4-stage causal world model: [8760 Parametric Load & Cooling] -> [Substation Headroom & PTDF Flow Delta] -> [Queue COD Slippage & P(eventual)] -> [5-Year Levered DCF IRR, DSCR & Capital at Delay Risk].
| Parameter | Type | Required | Notes |
|---|---|---|---|
| project_id | string | no | — |
| canonical_project_id | string | no | — |
| query | string | no | — |
| location | string | no | — |
| base_mw | number | no | — |
| delta_mw | number | no | — |
| transformer_lead_time_months_delta | number | no | — |
| delta_transformer_lead_weeks | number | no | — |
| nodal_lmp_basis_spread_delta | number | no | — |
| delta_nodal_basis_usd_mwh | number | no | — |
| interconnection_queue_cluster_mw_delta | number | no | — |
| delta_cluster_load_mw | number | no | — |
| wacc_delta_bps | number | no | — |
| delta_interest_rate_bps | number | no | — |
| enable_btm_flexibility | boolean | no | — |
| state | string | no | — |
Resolves data center campuses, candidate sites, or transmission substations to official ISO/RTO Pricing Nodes (PNodes), Settlement Points, and electrical bus identifiers across NYISO, PJM, ERCOT, MISO, CAISO, SPP, and ISO-NE. Returns bus nominal kV, day-ahead LMP, and congestion basis spread for production cost modeling.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| location | string | no | — |
| state | string | no | — |
| project_id | string | no | — |
| canonical_project_id | string | no | — |
| action | string | no | — |
| substation_name | string | no | — |
| target_interconnect_kv | number | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| radius_miles | number | no | — |
| max_distance_km | number | no | — |
| market | string | no | — |
Generates thermodynamic chronological 8,760-hour hourly load vectors (Real MW, Reactive MVAR, Apparent MVA, PUE) for data center campuses and greenfield parcels based on ambient temperature regression, cooling architecture, and compute workloads. Direct input for production cost and nodal market simulation engines.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| project_id | string | no | — |
| canonical_project_id | string | no | — |
| query | string | no | — |
| location | string | no | — |
| state | string | no | — |
| market | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| load_mw | number | no | — |
| it_capacity_mw | number | no | — |
| power_factor | number | no | — |
| pue | number | no | — |
| cooling_type | string | no | — |
| cooling_topology | string | no | — |
| workload_archetype | string | no | — |
| include_hourly_sample | boolean | no | — |
Comprehensive multi-vector site diligence evaluating physical grid proximity, substation headroom, water stress, flood/hazard exposure, environmental gates, and zoning feasibility.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| location | string | no | — |
| city | string | no | — |
| state | string | no | — |
| market | string | no | — |
| address | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| load_mw | number | no | — |
| target_mw | number | no | — |
| target_initial_energization_date | no | — | |
| target_energization_year | no | — | |
| cooling_assumption | string | no | — |
| cooling_type | string | no | — |
| include_opportunity_matrix | boolean | no | — |
Unified underwriting engine synthesizing project claims vs verified physical evidence, active ISO/RTO queue filings, study progression stages, and capital commitments.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| action | string | no | — |
| location | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| radius_miles | number | no | — |
| filters | string | no | — |
| query | string | no | — |
| project_id | string | no | — |
| project_name | string | no | — |
| state | string | no | — |
| country | string | no | — |
| record_class | no | — | |
| iso_rto | string | no | — |
| min_mw | number | no | — |
| min_capital_usd | number | no | — |
| capital_velocity_stage | string | no | — |
| has_capital_data | boolean | no | — |
| status | no | — | |
| provenance_type | string | no | — |
| study_stage | string | no | — |
Substation capacity intelligence, high-voltage transformer ratings, available MVA headroom, and estimated interconnection upgrade scopes/timelines.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| action | string | no | — |
| substation_name | string | no | — |
| target_interconnect_kv | number | no | — |
| substation_id | string | no | — |
| query | string | no | — |
| state | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| location | string | no | — |
| target_expansion_mw | number | no | — |
| requested_load_mw | number | no | — |
| target_mw | number | no | — |
| min_voltage_kv | number | no | — |
| headroom_class | string | no | — |
| include_bom | boolean | no | — |
| include_upgrade_scope | boolean | no | — |
| limit | integer | no | — |
| offset | integer | no | — |
| radius_miles | number | no | — |
High-voltage transmission line corridors (69 kV to 765 kV), circuit capacities, radial distances, and right-of-way routing constraints.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| latitude | number | no | — |
| longitude | number | no | — |
| location | string | no | — |
| query | string | no | — |
| state | string | no | — |
| min_voltage_kv | number | no | — |
| radius_miles | number | no | — |
| corridor_name | string | no | — |
| geographic_scope | string | no | — |
| include_grid_forecast | boolean | no | — |
| limit | integer | no | — |
| offset | integer | no | — |
Utility territory identification, EIA-861 retail power rates, large-load tariff schedules, contract demand ratchets, and flexibility/curtailment options.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| action | string | no | — |
| utility_name | string | no | — |
| utility_id | string | no | — |
| site_id | string | no | — |
| state | string | no | — |
| iso_rto | string | no | — |
| location | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| load_mw | number | no | — |
| target_mw | number | no | — |
| load_factor | number | no | — |
| flexible_pct | number | no | — |
| include_flexibility | boolean | no | — |
| include_interconnection | boolean | no | — |
| include_tariffs | boolean | no | — |
| include_rto_balance | boolean | no | — |
Operating and planned power plants, battery energy storage systems (BESS), natural gas interstate pipeline corridors, and brownfield thermal re-use sites.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| action | string | no | — |
| query | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| location | string | no | — |
| state | string | no | — |
| fuel_type | string | no | — |
| asset_type | string | no | — |
| fuel_type_filter | array | no | — |
| min_capacity_mw | number | no | — |
| min_generation_mw | number | no | — |
| radius_miles | number | no | — |
| operating_only | boolean | no | — |
| limit | integer | no | — |
| offset | integer | no | — |
Environmental constraint screening: baseline water stress, groundwater depletion, FEMA flood zones, seismic/wildfire hazard risks, and protected wetlands.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| location | string | no | — |
| state | string | no | — |
| radius_miles | number | no | — |
| load_mw | number | no | — |
| parcel_acres | number | no | — |
| cooling_type | string | no | — |
| include_insurance_risk | boolean | no | — |
Jurisdictional zoning classification, local ordinance requirements, moratorium risks, and community opposition sentiment analysis.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| state | string | no | — |
| location | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| radius_km | number | no | — |
| load_mw | number | no | — |
| county | string | no | — |
Long-haul and metro dark fiber routes, carrier density, route redundancy, and proximity to major carrier-neutral interconnection points.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| location | string | no | — |
| state | string | no | — |
| max_distance_km | number | no | — |
| radius_miles | number | no | — |
| limit | integer | no | — |
| offset | integer | no | — |
Wholesale LMP electricity price benchmarks, developer market share portfolios, news intelligence tracking, and supply chain critical materials.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| action | string | no | — |
| iso_rto | string | no | — |
| state | string | no | — |
| developer_name | string | no | — |
| comparison_peer | string | no | — |
| organization_name | string | no | — |
| company_name | string | no | — |
| material | string | no | — |
| query | string | no | — |
| days_back | integer | no | — |
| limit | integer | no | — |
| offset | integer | no | — |
Multi-vector spatial intelligence summary for a bounding box or radius: aggregates substation headroom, queue competition, water stress, fiber, and capital momentum.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| bbox | array | no | — |
| latitude | number | no | — |
| longitude | number | no | — |
| location | string | no | — |
| locationName | string | no | — |
| radius_miles | number | no | — |
| radiusKm | number | no | — |
| radius_km | number | no | — |
| state | string | no | — |
| weights | object | no | — |
- Every tool — any call limit is its publisher’s, not ours
- No card, and mcprush charges nothing for it
- Runs at its publisher’s own address — this marketplace is not in the path
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install AIxEnergy Map or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
| Term | Level | What it prices | Points |
|---|---|---|---|
| capability-exposure | minimal | capability blast radius (minimal) — client exposure if the model is manipulated | −0 |
| coverage-honesty | manifest | inspection depth (manifest) — how much of the target the scan could see | −4 |
What the scan could actually read
A grade is only as meaningful as its coverage, so the scanner publishes its own depth before it publishes its result.
The scan read each tool’s name, description, input schema and annotations exactly as the server listed them the last time it answered us; no code was reviewed. We ask the server again about once a month, and a list that changed is graded again.
The implementation source was not read — this reflects the declared tool metadata only.
Capability — what it could do if the model were manipulated
Tags derived from each tool’s schema and the implementation, not from what the tool calls itself. minimal is the level these add up to.
| Tool | Capability tags | Why the tag was assigned |
|---|---|---|
| underwrite_large_load_asset | no tags | |
| screen_regional_capacity | no tags | |
| profile_counterparty | no tags | |
| simulate_grid_to_capital_shock | no tags | |
| resolve_pnode_and_electrical_bus | no tags | |
| generate_parametric_8760_profile | no tags | |
| assess_site_feasibility | no tags | |
| underwrite_project_and_queue | no tags | |
| audit_substation_and_upgrades | no tags | |
| query_transmission_and_corridors | no tags | |
| evaluate_utility_and_tariffs | no tags | |
| query_fuel_and_generation_assets | no tags | |
| audit_environmental_and_site_gates | no tags | |
| query_policy_zoning_and_pushback | no tags | |
| query_telecom_and_dark_fiber | no tags | |
| benchmark_market_and_ecosystem | no tags | |
| query_area_intelligence_summary | no tags |
Toxic-flow graph
The lethal trifecta, checked as a graph rather than as a checklist: untrusted input, a sensitive source and an external sink have to meet before there is a path worth worrying about.
The public result for this release does not print the flow graph, so there is nothing to show here. That is not the same as "no paths were found": what the scan did read is above, under coverage.
Supply chain and provenance
This is the first scan of this surface here, so there is nothing yet to compare it against.
Every result on this tab comes from one deterministic pass over the published package — offline, rule by rule, and auditable line by line above. Same methodology version, same bytes, same score.
Release history
This is an address its publisher runs: which release it serves is theirs to choose, so there is nothing here to pin. The history below is for reading; the current release on file is 3.4.0.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish AIxEnergy Map can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.