Comprehensive Model Context Protocol server for managing Home Assistant through AI assistants.
Arc Flash Platform — Electrical Studies is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Electrical engineering calculations per the Brazilian standard (NBR), validated, with standards citations.
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user --transport http arc-flash-platform-estudos-eletricos-mcp https://arc-flash-platform.onrender.com/mcp
# 2 — ask your agent for something these tools do
# listar_ferramentas, calcular_energia_incidente, calcular_energia_incidente_hv and 18 more
Arc Flash Platform — Electrical Studies costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. Nothing here runs on your machine and nothing runs on ours: this server answers at its publisher’s own address, and what you install is the connection straight to it.
This is a public server: it answers at its publisher’s own address and this marketplace is not in the path. Claude Code registers it in one command; --scope user makes it available in every project. The transport below is http, as the publisher's own manifest declares it.
claude mcp add --scope user --transport http arc-flash-platform-estudos-eletricos-mcp https://arc-flash-platform.onrender.com/mcpReconnect, or start a new session, and the tools appear in the model’s tool list.
One config entry pointing straight at the publisher’s own address — this marketplace is not in the path, and nothing from this listing executes on your machine.
21 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Lista a prateleira de cálculos de engenharia elétrica e o tier de cada um.
No parameter schema on file.
Energia incidente (Ei, cal/cm²), LAS e categoria de EPI de um arco elétrico, pelo motor IEEE 1584:2018 / ABNT NBR 17227:2025 VALIDADO da plataforma (208 V– 15 kV). config ∈ {VCB,VCBB,HCB,VOA,HOA}. Dois patamares de corrente (IEEE 1584:2018 §4.12): t_arc_s = tempo de eliminação da proteção na corrente de arco PLENA (Iarc); t_arc_reduzido_s = tempo na corrente REDUZIDA (Imin ≈ 0,88·Iarc). Com
| Parameter | Type | Required | Notes |
|---|---|---|---|
| tensao_kv | number | yes | — |
| ibf_ka | number | yes | — |
| gap_mm | number | yes | — |
| dist_trabalho_mm | number | yes | — |
| t_arc_s | number | yes | — |
| config | string | no | — |
| t_arc_reduzido_s | no | — | |
| larg_mm | number | no | — |
| alt_mm | number | no | — |
| prof_mm | number | no | — |
| api_key | no | — |
Energia incidente para sistemas > 15 kV — FORA do IEEE 1584:2018 / NBR 17227 (arco ao ar livre fase-terra). É TRIAGEM, NÃO laudo: o motor IEEE 1584 da plataforma NÃO é usado; gap e configuração de eletrodos não se aplicam. metodo ∈ {osha (padrão), lee, epri}: • osha — OSHA 1910.269 Apêndice E, Tab. 6/7 (base ArcPro). tipo_trabalho ∈ {luva (Tab.6, 4–46 kV), vara (Tab.7, 4–800 kV)}. Devol
| Parameter | Type | Required | Notes |
|---|---|---|---|
| metodo | string | yes | — |
| tensao_kv | number | yes | — |
| ibf_ka | number | yes | — |
| t_ms | number | yes | — |
| dist_trabalho_mm | no | — | |
| tipo_trabalho | string | no | — |
| comprimento_arco_m | no | — | |
| api_key | no | — |
Curto-circuito (IEC 60909) pelo motor da plataforma: Icc 3φ/2φ/fase-terra, X/R e pico. Informe a rede por potencia_curto_mva OU icc_rede_kA. com_transformador=True dá o Icc no secundário (trafo_*). xr_rede/xr_trafo = relações X/R (regem κ, pico ip e assimetria — o making do disjuntor); tipo_aterramento ∈ {solido, resistivo, isolado} + Rn_ohm regem a corrente de falta fase-terra (Icc_
| Parameter | Type | Required | Notes |
|---|---|---|---|
| tensao_kv | number | yes | — |
| potencia_curto_mva | no | — | |
| com_transformador | boolean | no | — |
| trafo_kVA | number | no | — |
| trafo_Vcc_pct | number | no | — |
| trafo_V2_kv | number | no | — |
| xr_rede | number | no | — |
| xr_trafo | no | — | |
| tipo_aterramento | string | no | — |
| Rn_ohm | number | no | — |
| icc_rede_kA | no | — | |
| com_cabo | boolean | no | — |
| cabo_secao_mm2 | number | no | — |
| cabo_material | string | no | — |
| cabo_m | number | no | — |
| cabo_num_condutores | integer | no | — |
| fator_c | no | — | |
| aplicar_kt | boolean | no | — |
| api_key | no | — |
Monta uma REDE MULTIBARRA (concessionária → transformadores → cabos → quadros) e calcula o curto-circuito IEC 60909 em TODAS as barras de uma vez, pelo mesmo motor validado da plataforma (redução nodal do Anexo B: aceita alimentação radial, em paralelo e malha). Use quando o usuário tem os dados de VÁRIOS equipamentos — típico de quem acabou de ler um datasheet, uma carta da concessionária ou um m
| Parameter | Type | Required | Notes |
|---|---|---|---|
| barras | array | yes | — |
| elementos | array | yes | — |
| fonte | object | yes | — |
| motores | no | — | |
| lang | string | no | — |
| estudo | no | — | |
| api_key | no | — |
Tempo de atuação de um dispositivo de proteção à corrente de falta, pela curva composta 4-segmentos do motor da plataforma (IEC 60255-151 / IEEE C37.112): 51 inversa · 50 curto-tempo · 50 instantânea. É o ELO entre o curto e o arco: encadeie calcular_curto_circuito → tempo_de_atuacao → calcular_energia_incidente (o tempo_s daqui é o t_arc_s, o parâmetro mais difícil de estimar à mão). O tempo
| Parameter | Type | Required | Notes |
|---|---|---|---|
| corrente_falta_A | number | yes | — |
| pickup_A | no | — | |
| curva | string | no | — |
| tms | no | — | |
| instantaneo_A | no | — | |
| t_disjuntor_ms | number | no | — |
| curto_tempo_A | no | — | |
| t_curto_tempo_ms | number | no | — |
| device_id | no | — | |
| tolerancia_pct | no | — | |
| curva_pontos | no | — | |
| curva_base | no | — | |
| api_key | no | — |
Lista o catálogo de dispositivos (devices_db) para descobrir o device_id usado no modo catálogo de tempo_de_atuacao. Por padrão só MCCB/ACB (trip eletrônico com In_A real); tipo filtra ('MCCB','ACB','Relay','MCB','Fuse','Transformer') e mostra aquele tipo mesmo fora do modo catálogo (relé serve à rota manual); todos=True inclui todos os tipos. Gratuito (uso limitado).
| Parameter | Type | Required | Notes |
|---|---|---|---|
| tipo | no | — | |
| todos | boolean | no | — |
| api_key | no | — |
Memorial assinável + etiqueta ANSI/NBR. NUNCA é emitido autonomamente por IA — o documento é preparado na sua conta da plataforma para revisão e assinatura do responsável técnico.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| referencia_calculo | string | yes | — |
| api_key | no | — |
Encaminha um pedido de ORÇAMENTO de estudo/laudo assinável com ART (arc flash, curto-circuito, seletividade, adequação NR-10) direto do chat. Informe o e-mail de contato e o escopo (ex.: nº de painéis, classe de tensão, prazo, cidade). A equipe responde pelo e-mail informado. Não consome o limite das calculadoras — funciona inclusive quando o uso gratuito do dia esgotou.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| string | yes | — | |
| escopo | string | no | — |
| empresa | string | no | — |
| nome | string | no | — |
| api_key | no | — |
Dimensiona a seção de um cabo BT pela ABNT NBR 5410: ampacidade (Tab. 36-39 + fatores), queda de tensão, coordenação de sobrecarga (§5.3.4.1), neutro e PE. sistema ∈ {1FN,2F,3F,3FN}; metodo = método de instalação (A1,A2,B1,B2,C,D,E,F,G); material ∈ {Cu,Al}; isolacao ∈ {PVC,EPR}. icc_quadro_kA = Icc presumida no quadro de origem. n_circuitos_agrupados = nº de circuitos no mesmo eletrodu
| Parameter | Type | Required | Notes |
|---|---|---|---|
| potencia_W | number | yes | — |
| tensao_V | number | yes | — |
| comprimento_m | number | yes | — |
| sistema | string | no | — |
| metodo | string | no | — |
| material | string | no | — |
| isolacao | string | no | — |
| fp | number | no | — |
| temp_ambiente_C | number | no | — |
| queda_max_pct | number | no | — |
| icc_quadro_kA | number | no | — |
| n_circuitos_agrupados | integer | no | — |
| arranjo | string | no | — |
| disjuntor_In_A | no | — | |
| curva_disjuntor | string | no | — |
| api_key | no | — |
Verifica a proteção contra choque por seccionamento automático (ABNT NBR 5410:2004 §5.1.2.2). TN: Zs ≤ U0/Ia (informe Ia OU disjuntor In+curva_mcb). TT: RA ≤ 50/IΔn (informe i_dn_mA + RA). situacao = 1 (seco/usual, U_L=50 V) ou 2 (molhado/externo, U_L=25 V e tempo da Tab. 25 mais rígido). R_montante_ohm+X_montante_ohm = impedância do laço A MONTANTE (fonte/trafo + alimentadores) — sem ela o
| Parameter | Type | Required | Notes |
|---|---|---|---|
| U0_V | number | yes | — |
| sistema | string | no | — |
| Ia_A | no | — | |
| disjuntor_In_A | no | — | |
| curva_mcb | no | — | |
| secao_fase_mm2 | number | no | — |
| comprimento_m | number | no | — |
| material | string | no | — |
| i_dn_mA | no | — | |
| RA_ohm | no | — | |
| situacao | integer | no | — |
| R_montante_ohm | number | no | — |
| X_montante_ohm | number | no | — |
| circuito_tipo | string | no | — |
| secao_pe_mm2 | no | — | |
| T_op | number | no | — |
| api_key | no | — |
Dimensiona o banco de capacitores para corrigir o fator de potência à meta (REN ANEEL nº 1.000; FP-alvo padrão 0,92). Com tensao_kV também dá a corrente nominal do banco e a norma (IEC 60831/60871). Un_cap_kV = tensão de placa do capacitor: se ele opera abaixo da Un, entrega MENOS kvar (derating Q∝V²) e a correção real cai — informe p/ não superestimar. carga_min_pct = carregamento mínimo (%
| Parameter | Type | Required | Notes |
|---|---|---|---|
| potencia_kW | number | yes | — |
| fp_atual | number | yes | — |
| fp_meta | number | no | — |
| tensao_kV | no | — | |
| Un_cap_kV | no | — | |
| carga_min_pct | no | — | |
| scc_MVA | no | — | |
| api_key | no | — |
Dimensiona o TC de proteção (IEC 61869-2 / NBR 6856): menor primário comercial que NÃO satura na falta, considerando o burden REAL (relé+fiação) e o ALF efetivo. xr (X/R) = liga o critério de saturação na falta ASSIMÉTRICA (offset CC, IEEE C37.110): um TC que passa no simétrico pode saturar no transitório, atrasar o relé e ELEVAR a energia incidente de arco. I_load_A+Fter = corrente de carga
| Parameter | Type | Required | Notes |
|---|---|---|---|
| Icc_A | number | yes | — |
| secundario_A | number | yes | — |
| relay_ohm | number | yes | — |
| cable_ohm | number | yes | — |
| ALF | no | — | |
| burden_VA | no | — | |
| xr | no | — | |
| I_load_A | no | — | |
| Rct_ohm | no | — | |
| Fter | number | no | — |
| Ith_A | no | — | |
| Idyn_A | no | — | |
| t_curto_s | number | no | — |
| tth_s | number | no | — |
| primario_A | no | — | |
| primario_pleno_A | no | — | |
| classe_abnt | no | — | |
| pickup_sec_A | no | — | |
| remanencia_pct | no | — | |
| api_key | no | — |
Afundamento de tensão na partida de motor por divisor fasorial fonte→cabo→motor (C ∝ V²). fonte_tipo ∈ {scc (nível de curto scc_MVA), trafo (fonte_trafo_kVA+fonte_trafo_Vcc_pct, com rede a montante opcional fonte_scc_montante_MVA), gerador (fonte_gmg_kVA+fonte_gmg_xd_pct, X'd transitório)} — trafo dedicado e GMG são os casos SEVEROS de afundamento. metodo ∈ {direta, estrela_triangu
| Parameter | Type | Required | Notes |
|---|---|---|---|
| potencia_kW | number | yes | — |
| tensao_V | number | yes | — |
| scc_MVA | no | — | |
| eta | number | no | — |
| fp | number | no | — |
| Ip_In | number | no | — |
| metodo | string | no | — |
| fp_partida | number | no | — |
| Cp_Cn | number | no | — |
| C_load_pu | no | — | |
| dv_limite_pct | number | no | — |
| In_A | no | — | |
| cabo_mm2 | no | — | |
| cabo_m | number | no | — |
| fonte_tipo | string | no | — |
| fonte_trafo_kVA | no | — | |
| fonte_trafo_Vcc_pct | number | no | — |
| fonte_scc_montante_MVA | no | — | |
| fonte_gmg_kVA | no | — | |
| fonte_gmg_xd_pct | number | no | — |
Elevação de temperatura do ar interno de um painel BT (IEC 60890) e verificação de aceitação (61439-1). perda_W = perdas dissipadas no invólucro; dimensões em metros. Exposição das faces (muda a área de resfriamento): face_topo ∈ {exposto,coberto}; face_traseira/face_laterais ∈ {exposta,coberta} (coberta = encostada na parede / em fila → aquece mais). tipo_instalacao 1–5 (Fig. 4); `limit
| Parameter | Type | Required | Notes |
|---|---|---|---|
| perda_W | number | yes | — |
| altura_m | number | yes | — |
| largura_m | number | yes | — |
| profundidade_m | number | yes | — |
| ventilado | boolean | no | — |
| area_ventilacao_cm2 | no | — | |
| n_particoes | integer | no | — |
| temp_ambiente_C | number | no | — |
| face_topo | string | no | — |
| face_traseira | string | no | — |
| face_laterais | string | no | — |
| tipo_instalacao | integer | no | — |
| limite_equip_C | no | — | |
| regime | string | no | — |
| api_key | no | — |
Tração de puxamento de cabo (IEEE 1185/525): tração no cabrestante, SWBP (pressão lateral nas curvas), ocupação do duto (NBR 5410) e tração máxima admissível. n_cabos ∈ {1,3} (trifólio). curvas_graus = lista dos ângulos das curvas/cotovelos (graus) — SEM curvas a SWBP (que costuma GOVERNAR) sai zero; curva_raio_m = raio das curvas (m). attachment ∈ {olhal (no condutor), malha (na capa, tet
| Parameter | Type | Required | Notes |
|---|---|---|---|
| secao_mm2 | number | yes | — |
| material | string | yes | — |
| od_mm | number | yes | — |
| peso_kg_m | number | yes | — |
| duto_D_mm | number | yes | — |
| comprimento_m | number | yes | — |
| n_cabos | integer | no | — |
| incl_graus | number | no | — |
| mu | number | no | — |
| curvas_graus | no | — | |
| curva_raio_m | number | no | — |
| attachment | string | no | — |
| convencao | string | no | — |
| swbp_classe | string | no | — |
| cabo_classe | string | no | — |
| api_key | no | — |
Afundamento transitório de tensão ao aplicar um degrau de carga a um grupo gerador (ISO 8528-5, etapa 1: tensão), via reatância transitória X'd. modo ∈ {bloco (degrau_kVA+degrau_fp), motor (motor_kW, partida DOL)}. XR = X/R da X'd (ângulo da queda). cabo_mm2+cabo_m = alimentador gerador→carga (a queda no cabo soma no ΔV). dv_limite_pct sobrepõe o limite da classe — OBRIGATÓRIO para `clas
| Parameter | Type | Required | Notes |
|---|---|---|---|
| tensao_V | number | yes | — |
| Sn_kVA | number | yes | — |
| xd_pct | number | no | — |
| XR | number | no | — |
| modo | string | no | — |
| degrau_kVA | no | — | |
| degrau_fp | number | no | — |
| motor_kW | no | — | |
| motor_Ip_In | number | no | — |
| motor_fp_rotor_bloqueado | number | no | — |
| classe_iso | string | no | — |
| dv_limite_pct | no | — | |
| cabo_mm2 | no | — | |
| cabo_m | number | no | — |
| api_key | no | — |
Curva de dano a faltas passantes do transformador (IEEE C57.109/C57.12.59): categoria, corrente de falta passante máxima (In/Z), ponto ANSI e ponto de inrush — para coordenar a proteção a montante. fases ∈ {3ph,1ph}; frequencia_falta ∈ {infrequent,frequent}; tipo ∈ {liquid,dry}; t_inrush_ms = patamar de tempo do ponto de inrush. ligacao (IEEE C37.91) refere a curva ao OUTRO lado para coo
| Parameter | Type | Required | Notes |
|---|---|---|---|
| Sn_kVA | number | yes | — |
| Vn_kV | number | yes | — |
| Vcc_pct | number | yes | — |
| fases | string | no | — |
| frequencia_falta | string | no | — |
| tipo | string | no | — |
| k_inrush | number | no | — |
| t_inrush_ms | number | no | — |
| ligacao | string | no | — |
| api_key | no | — |
Simula a partida DIRETA no tempo (RK4, J·dω/dt = T_motor − T_carga): tempo de aceleração, se o motor PARTE ou trava, e o térmico de rotor bloqueado (I²t da partida vs tempo de rotor bloqueado de placa, critério Petrobras N-313). polos = nº de polos; inercia_kgm2 = J total (motor+carga); tipo_carga ∈ {constante, linear, parabolica (bomba/ventilador)}; conjugado_partida_carga_pu /`conjugado_
| Parameter | Type | Required | Notes |
|---|---|---|---|
| potencia_kW | number | yes | — |
| tensao_V | number | yes | — |
| polos | integer | yes | — |
| scc_MVA | number | yes | — |
| inercia_kgm2 | number | yes | — |
| tipo_carga | string | no | — |
| conjugado_partida_carga_pu | number | no | — |
| conjugado_pleno_pu | number | no | — |
| eta | number | no | — |
| fp | number | no | — |
| Ip_In | number | no | — |
| fp_partida | number | no | — |
| Cp_Cn | number | no | — |
| t_rotor_bloqueado_s | no | — | |
| cabo_mm2 | no | — | |
| cabo_m | number | no | — |
| api_key | no | — |
Banco dessintonizado ou filtro sintonizado (reator série com o capacitor). Informe p_pct (fator XL/XC, ex.: 7 ou 14) OU L_mH. Devolve a tensão ELEVADA no capacitor V/(1−p), a corrente pelo reator, o reativo efetivo Q/(1−p), a frequência de sintonia e a classe de tensão sugerida do capacitor (IEC 60831). A leitura do ramo segue a sintonia: a partir de p = 5,67 % (4,2ª) é banco dessintonizado; e
| Parameter | Type | Required | Notes |
|---|---|---|---|
| Q_kvar | number | yes | — |
| tensao_kV | number | yes | — |
| p_pct | no | — | |
| L_mH | no | — | |
| scc_MVA | no | — | |
| Un_cap_kV | no | — | |
| api_key | no | — |
K-factor (UL 1561) a partir do espectro de corrente {ordem: % de I1}, ex.: {"3": 70, "5": 45, "7": 30}. Devolve o K-factor, o K-rating comercial (trafo K-rated para cargas não-lineares), o F_HL (derating de perdas parasitas, IEEE C57.110) e o THD de corrente. Gratuito.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| espectro_harmonico | object | yes | — |
| api_key | no | — |
- Every tool — any call limit is its publisher’s, not ours
- No card, and mcprush charges nothing for it
- Runs at its publisher’s own address — this marketplace is not in the path
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install Arc Flash Platform — Electrical Studies or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
This listing is an address its publisher runs, and you connect to it directly — this marketplace is not in the path. The scanner reads packages and public source, and an address is neither. So there is no grade — not a withheld one, an unmeasured one.
Release history
This is an address its publisher runs: which release it serves is theirs to choose, so there is nothing here to pin. The history below is for reading; the current release on file is 1.0.0.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish Arc Flash Platform — Electrical Studies can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.