Configure and automate Home Assistant with Claude, ChatGPT, and other AI assistants.
Ardenvale Construction Tools is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Planning tools for commercial and industrial construction.
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user --transport http ardenvale-construction-tools-mcp https://ardenvaleconstruction.com/mcp
# 2 — ask your agent for something these tools do
# office_space_calculator, occupant_load_calculator, washroom_fixture_calculator and 6 more
Ardenvale Construction Tools costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. Nothing here runs on your machine and nothing runs on ours: this server answers at its publisher’s own address, and what you install is the connection straight to it.
This is a public server: it answers at its publisher’s own address and this marketplace is not in the path. Claude Code registers it in one command; --scope user makes it available in every project. The transport below is http, as the publisher's own manifest declares it.
claude mcp add --scope user --transport http ardenvale-construction-tools-mcp https://ardenvaleconstruction.com/mcpReconnect, or start a new session, and the tools appear in the model’s tool list.
One config entry pointing straight at the publisher’s own address — this marketplace is not in the path, and nothing from this listing executes on your machine.
9 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Estimate usable and rentable office square feet from headcount, growth, desk sharing, rooms, circulation and load factor. Preliminary planning estimate only. The architect's test fit, the building drawings and the permit set govern the actual layout.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| employees | integer | yes | Employees now (required). Unit: people. |
| growth_pct | number | no | Expected growth over the lease term. Unit: percent. |
| pattern | string | no | Work pattern. Sets the default desk sharing ratio. |
| people_per_desk | number | no | Desk sharing ratio, 1 or more. Default follows pattern: office 1, hybrid 1.5, remote 3. Unit: people per desk. |
| private_offices | integer | no | Private offices. Unit: count. |
| small_meeting_rooms | integer | no | Small meeting rooms (up to 4 people). Unit: count. |
| medium_meeting_rooms | integer | no | Medium meeting rooms (up to 8 people). Unit: count. |
| large_meeting_rooms | integer | no | Large meeting rooms (12 or more people). Unit: count. |
| reception | boolean | no | Include a reception area. |
| kitchen_sqft | number | no | Kitchen and break area. 0 for none. Unit: sq ft. |
| storage_room | boolean | no | Include a storage or server room. |
| area_workstation_sqft | number | no | Area per workstation. Unit: sq ft each. |
| area_private_office_sqft | number | no | Area per private office. Unit: sq ft each. |
| area_small_meeting_sqft | number | no | Area per small meeting room. Unit: sq ft each. |
| area_medium_meeting_sqft | number | no | Area per medium meeting room. Unit: sq ft each. |
| area_large_meeting_sqft | number | no | Area per large meeting room. Unit: sq ft each. |
| area_reception_sqft | number | no | Reception area. Unit: sq ft. |
| area_storage_sqft | number | no | Storage or server room area. Unit: sq ft. |
| circulation_pct | number | no | Circulation allowance added to the components. Unit: percent. |
| load_factor_pct | number | no | Load factor: rentable = usable x (1 + load factor). Unit: percent. |
Minimum design occupant load for a floor area from Ontario Building Code Table 3.1.17.1 area per person values. Preliminary planning figure only. The architect, the engineer and the permit set govern the occupant load used for design and approval.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| use | string | yes | Use of the floor area (required). One slug, or several separated by commas to match area. |
| area | number | yes | Floor area for each use (required). Comma separated when several uses are given. Unit: unit. |
| unit | string | no | Area unit. |
Minimum water closets and lavatories for each sex in an Ontario office or retail space (Building Code Tables 3.7.4.7 and 3.7.4.8). Preliminary planning figure only. Accessible and universal washroom rules apply separately. The architect, the engineer and the permit set govern.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| type | string | no | Occupancy: office (Group D, Table 3.7.4.7) or retail (Group E, Table 3.7.4.8). |
| persons | integer | yes | Occupant load (office) or employees at one time (retail). Required. Unit: people. |
| male_pct | number | no | Share counted as male, 0 to 100. The rest are counted as female. Unit: percent. |
| public | integer | no | Retail only: customers at one time. Unit: people. |
| area_m2 | number | no | Retail only: total area excluding basements. Unit: m2. |
| urinals | boolean | no | Use urinals for males up to the Code limit. |
Check indoor play space, outdoor play space and sleeping area per child for an Ontario licensed child care centre. Preliminary planning check only. Licensing is decided by the ministry. The architect, the engineer and the permit set govern the design.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| groups | string | yes | Required. Licensed age groups as group:children:floor_area, comma separated, for example preschool:24:70,infant:10:25. |
| unit | string | no | Area unit for every area value. |
| outdoor_area | number | no | Outdoor play space available. 0 shows only the requirement. Unit: unit. |
| six_hours | boolean | no | Program runs six hours or more in a day. |
| sleeping_area | number | no | Sleeping area available. Unit: unit. |
| sleeping_children | integer | no | Children sleeping at one time. Unit: children. |
Occupant load, seat capacity and minimum patron and employee water closets and lavatories for an Ontario restaurant or bar (Building Code Table 3.7.4.3.-D, -E and -F). Preliminary planning figure only. The architect, the public health unit, the building official and the permit set govern the seat count and the fixture count.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| dining_area_m2 | number | yes | Dining, beverage and cafeteria floor area open to patrons (required). Unit: m2. |
| seats | integer | no | Seats planned. 0 to use the occupant load from the area. The occupant load is the larger of the two. Unit: seats. |
| service | string | no | restaurant: a dining room or cafeteria (Table 3.7.4.3.-D). bar: an establishment used primarily for alcoholic beverages with limited or no food service (Table 3.7.4.3.-E). |
| employees | integer | no | Employees normally present at one time, those present more than 25 percent of the working day (Sentence 3.7.4.3.(9)). Unit: people. |
| male_pct | number | no | Share counted as male, 0 to 100. The rest are counted as female. Unit: percent. |
| urinals | boolean | no | Use urinals for males up to the Code limit. |
| storeys | integer | no | Storeys in the building (sets the minimum number of universal washrooms). Unit: storeys. |
Required exit width, number of exits, door count and travel distance limit for an occupant load under Ontario Building Code Subsections 3.4.2 and 3.4.3. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the means of egress.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| occupant_load | integer | yes | Occupant load of the floor area served (required). Use the occupant load calculator for the table value. Unit: persons. |
| group | string | no | Major occupancy of the floor area. |
| sprinklered | boolean | no | Floor area sprinklered throughout. |
| storeys | integer | no | Building height in storeys. Unit: storeys. |
| element | string | no | Exit element to size in the headline answer. |
| door_clear_width_mm | number | no | Clear opening of one door leaf you plan to use, 850 mm or more. Unit: mm. |
| stairs_storeys_served | integer | no | Storeys the exit stair serves above the lowest exit level. Over 2 sets the 1,100 mm minimum stair width. Unit: storeys. |
| floor_area_m2 | number | no | Floor area, to test the one-exit option. Unit: m2. |
| travel_distance_m | number | no | Longest travel distance from any point to an exit, measured along the path of travel. Unit: m. |
| max_diagonal_m | number | no | Maximum diagonal dimension of the floor area, to find the least distance between two exits. Unit: m. |
Pass or fail check of barrier-free stall, ambulatory stall or universal washroom clear dimensions against Ontario Building Code Articles 3.8.3.8 and 3.8.3.12. Preliminary clearance check only. The architect, the accessibility consultant and the building official govern. This does not certify a washroom.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| type | string | no | stall: barrier-free water closet stall. ambulatory: ambulatory stall. universal: universal washroom. |
| stall_width_mm | number | no | Stall clear width (stall and ambulatory). Unit: mm. |
| stall_depth_mm | number | no | Stall clear depth (stall and ambulatory). Unit: mm. |
| front_clear_diameter_mm | number | no | Stall only: diameter of clear floor space in front of the stall. Unit: mm. |
| door_clear_opening_mm | number | no | Door clear opening with the door open (all types). Unit: mm. |
| door_swing | string | no | Stall door swing. |
| inward_door_clear_area_ok | boolean | no | Stall with inward door: is a clear floor area of 820 mm by 1,440 mm inside the stall, clear of the door swing? |
| wc_centre_to_wall_mm | number | no | Stall only: water closet centre line to the nearest side wall. Unit: mm. |
| transfer_space_width_mm | number | no | Stall only: clear transfer space width beside the water closet. Unit: mm. |
| transfer_space_depth_mm | number | no | Stall only: clear transfer space depth beside the water closet. Unit: mm. |
| seat_height_mm | number | no | Stall only: water closet seat height above the floor. Unit: mm. |
| stall_face_to_door_mm | number | no | Stall with inward washroom door: clearance from stall face to that door. Unit: mm. |
| stall_face_to_obstruction_mm | number | no | Stall only: clearance from stall face to any wall-mounted fixture or obstruction. Unit: mm. |
| room_width_mm | number | no | Universal washroom internal width. Unit: mm. |
| room_length_mm | number | no | Universal washroom internal length. Unit: mm. |
| turning_diameter_mm | number | no | Universal washroom: diameter of open turning space. Unit: mm. |
| power_door_operator | boolean | no | Universal washroom: power door operator fitted. |
| latch_height_mm | number | no | Universal washroom: latch height above the floor. Unit: mm. |
| change_table_space_width_mm | number | no | Universal washroom: clear space width for an adult change table. Unit: mm. |
| change_table_space_length_mm | number | no | Universal washroom: clear space length for an adult change table. Unit: mm. |
Occupant load, exits, aisle widths and accessible route for an Ontario retail store, with a fixture run estimate from shelving depth. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the layout and the means of egress.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| floor_area_m2 | number | yes | Retail floor area on the storey (required). Unit: m2. |
| storey | string | no | Storey type, which sets the area per person: first (basement or first storey, 3.70 m2), upper-entrance (second storey with principal entrance from a pedestrian thoroughfare or parking area, 3.70 m2), |
| sprinklered | boolean | no | Floor area sprinklered throughout. |
| storeys | integer | no | Building height in storeys. Unit: storeys. |
| aisle_width_mm | number | no | Clear aisle width you plan between fixtures. Unit: mm. |
| fixture_depth_mm | number | no | Depth of one fixture run (for example a double-sided gondola). Unit: mm. |
| door_clear_width_mm | number | no | Clear opening of one door leaf, 850 mm or more. Unit: mm. |
| store_width_m | number | no | Store width, to estimate the number of fixture runs. Depth is area divided by width. Unit: m. |
| travel_distance_m | number | no | Longest travel distance from any point to an exit. Unit: m. |
Indicative parking stall count for a change of use in Toronto, Mississauga or Brampton from the zoning by-law rates, with the by-law named. Confirm with the municipality. Indicative only. Parking requirements differ by municipality, zone and site-specific exceptions. Confirm with the municipality's zoning examiner.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| city | string | yes | Municipality (required). Only cities whose by-law we opened are offered. |
| use | string | yes | Proposed use (required). Not every use is mapped for every city. |
| gross_floor_area_m2 | number | yes | Gross floor area of the use (required). Each by-law defines its own gross floor area. Unit: m2. |
| zone | string | no | Toronto: parking zone pza, pzb or other. Mississauga: parking precinct 1, 2, 3 or 4. Ignored for Brampton. |
| brampton_core | boolean | no | Brampton only: the property is inside the Downtown, Central Area and Hurontario/Main Corridor area (Schedule B-7), which has no minimum. |
- Every tool — any call limit is its publisher’s, not ours
- No card, and mcprush charges nothing for it
- Runs at its publisher’s own address — this marketplace is not in the path
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install Ardenvale Construction Tools or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
| Term | Level | What it prices | Points |
|---|---|---|---|
| capability-exposure | minimal | capability blast radius (minimal) — client exposure if the model is manipulated | −0 |
| coverage-honesty | manifest | inspection depth (manifest) — how much of the target the scan could see | −4 |
What the scan could actually read
A grade is only as meaningful as its coverage, so the scanner publishes its own depth before it publishes its result.
The scan read each tool’s name, description, input schema and annotations exactly as the server listed them the last time it answered us; no code was reviewed. We ask the server again about once a month, and a list that changed is graded again.
The implementation source was not read — this reflects the declared tool metadata only.
Capability — what it could do if the model were manipulated
Tags derived from each tool’s schema and the implementation, not from what the tool calls itself. minimal is the level these add up to.
| Tool | Capability tags | Why the tag was assigned |
|---|---|---|
| office_space_calculator | no tags | |
| occupant_load_calculator | no tags | |
| washroom_fixture_calculator | no tags | |
| child_care_space_checker | no tags | |
| restaurant_seating_and_washroom_requirement | no tags | |
| exit_width_and_egress_door_calculator | no tags | |
| accessible_washroom_clearance_checker | no tags | |
| retail_store_layout_and_aisle_width_calculator | no tags | |
| parking_stall_count_for_change_of_use | no tags |
Toxic-flow graph
The lethal trifecta, checked as a graph rather than as a checklist: untrusted input, a sensitive source and an external sink have to meet before there is a path worth worrying about.
The public result for this release does not print the flow graph, so there is nothing to show here. That is not the same as "no paths were found": what the scan did read is above, under coverage.
Supply chain and provenance
This is the first scan of this surface here, so there is nothing yet to compare it against.
Every result on this tab comes from one deterministic pass over the published package — offline, rule by rule, and auditable line by line above. Same methodology version, same bytes, same score.
Release history
This is an address its publisher runs: which release it serves is theirs to choose, so there is nothing here to pin. The history below is for reading; the current release on file is 1.0.0.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish Ardenvale Construction Tools can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.