Configure and automate Home Assistant with Claude, ChatGPT, and other AI assistants.
BRAINIAC Solar PV Design Calculations is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Paid Solar PV Design Calculations API via x402. Unpaid tool calls return 402.
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user --transport http brainiac-solar-pv-design-calculations-mcp https://www.brainiac.software/mcp/solar-design
# 2 — ask your agent for something these tools do
# solar-design_string-sizing, solar-design_dc-ac-ratio-check, solar-design_poa-irradiance-transpose and 11 more
BRAINIAC Solar PV Design Calculations costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. Nothing here runs on your machine and nothing runs on ours: this server answers at its publisher’s own address, and what you install is the connection straight to it.
This is a public server: it answers at its publisher’s own address and this marketplace is not in the path. Claude Code registers it in one command; --scope user makes it available in every project. The transport below is http, as the publisher's own manifest declares it.
claude mcp add --scope user --transport http brainiac-solar-pv-design-calculations-mcp https://www.brainiac.software/mcp/solar-designReconnect, or start a new session, and the tools appear in the model’s tool list.
One config entry pointing straight at the publisher’s own address — this marketplace is not in the path, and nothing from this listing executes on your machine.
14 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Compute minimum and maximum modules per series string and maximum parallel strings per MPPT from module temperature coefficients, site temperatures and inverter DC limits. Price $0.03 USDC. POST /api/v1/solar-design/string-sizing. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| module | object | yes | module, object. Required. |
| site | object | yes | site, object. Required. |
| inverter | object | yes | inverter, object. Required. |
Compute the DC/AC ratio and optionally estimate AC energy and clipping from a caller DC power series with constant efficiency or a PVWatts inverter curve. Price $0.03 USDC. POST /api/v1/solar-design/dc-ac-ratio-check. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| dcNameplateKw | number | yes | dcNameplateKw, number. Required. |
| acRatingKw | number | yes | acRatingKw, number. Required. |
| inverterEfficiency | number | no | inverterEfficiency, number, from any to 1. Required. |
| dcPowerSeriesKw | array | no | dcPowerSeriesKw, array. Optional. |
| intervalHours | number | no | intervalHours, number. Required. |
| ratioWarnAbove | number | no | ratioWarnAbove, number. Required. |
| useCecCurve | boolean | no | useCecCurve, boolean. Required. |
Compute plane-of-array irradiance with isotropic, Hay-Davies or Perez sky models and NREL SPA solar geometry from caller irradiance records. Price $0.04 USDC. POST /api/v1/solar-design/poa-irradiance-transpose. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| latitude | number | yes | latitude, number, from -90 to 90. Required. |
| longitude | number | yes | longitude, number, from -180 to 180. Required. |
| elevation | number | no | elevation, number. Required. |
| tilt | number | yes | tilt, number, from 0 to 90. Required. |
| azimuth | number | yes | azimuth, number, from 0 to 360. Required. |
| albedo | number | no | albedo, number, from 0 to 1. Required. |
| model | string | no | model, string, one of isotropic, haydavies, perez. Required. |
| records | array | yes | records, array. Required. |
| pressurePa | number | no | pressurePa, number. Required. |
| temperatureC | number | no | temperatureC, number. Required. |
| deltaT | number | no | deltaT, number. Required. |
Estimate AC energy from caller POA irradiance and temperatures using the PVWatts v5 DC and inverter models with a transparent loss stack. Price $0.04 USDC. POST /api/v1/solar-design/energy-yield-estimate. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| dcNameplateW | number | yes | dcNameplateW, number. Required. |
| gammaPdc | number | yes | gammaPdc, number. Required. |
| acRatingW | number | yes | acRatingW, number. Required. |
| inverterNominalEfficiency | number | no | inverterNominalEfficiency, number, from any to 1. Required. |
| lossesPercent | number | no | lossesPercent, number, from 0 to 100. Required. |
| temperatureModel | object | no | temperatureModel, object. Optional. |
| records | array | no | records, array. Optional. |
| monthly | array | no | monthly, array. Optional. |
| intervalHours | number | no | intervalHours, number. Required. |
Compute row height, shadow gap, row pitch and ground coverage ratio that avoid row-to-row shading at a design sun position. Price $0.02 USDC. POST /api/v1/solar-design/row-spacing. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| moduleSlopeLength | number | yes | moduleSlopeLength, number. Required. |
| tilt | number | yes | tilt, number, from 0 to 90. Required. |
| arrayAzimuth | number | no | arrayAzimuth, number, from 0 to 360. Required. |
| sun | object | no | sun, object. Optional. |
| designTimes | array | no | designTimes, array. Optional. |
| latitude | number | no | latitude, number, from -90 to 90. Optional. |
| longitude | number | no | longitude, number, from -180 to 180. Optional. |
| elevation | number | no | elevation, number. Required. |
| groundSlope | number | no | groundSlope, number. Required. |
Estimate beam and isotropic sky-diffuse losses caused by a caller far-field horizon profile against sun positions and beam POA. Price $0.03 USDC. POST /api/v1/solar-design/horizon-shading-loss. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| horizon | array | yes | horizon, array. Required. |
| records | array | no | records, array. Optional. |
| latitude | number | no | latitude, number, from -90 to 90. Optional. |
| longitude | number | no | longitude, number, from -180 to 180. Optional. |
| elevation | number | no | elevation, number. Required. |
| times | array | no | times, array. Optional. |
| beamPoa | array | no | beamPoa, array. Optional. |
Combine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories. Price $0.01 USDC. POST /api/v1/solar-design/system-loss-stack. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| losses | object | no | losses, object. Required. |
| useDefaultsForMissing | boolean | no | useDefaultsForMissing, boolean. Required. |
Size battery energy and inverter continuous/surge power needed to back up critical loads for a target autonomy with DoD and efficiency derates. Price $0.03 USDC. POST /api/v1/solar-design/battery-backup-sizing. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| loads | array | yes | loads, array. Required. |
| autonomyHours | number | yes | autonomyHours, number. Required. |
| depthOfDischarge | number | yes | depthOfDischarge, number, from any to 1. Required. |
| dischargeEfficiency | number | yes | dischargeEfficiency, number, from any to 1. Required. |
| temperatureDerate | number | no | temperatureDerate, number, from any to 1. Required. |
| inverterMargin | number | no | inverterMargin, number. Required. |
| pvRechargeKwhPerDay | number | no | pvRechargeKwhPerDay, number, from 0 to any. Required. |
| simultaneousStart | boolean | no | simultaneousStart, boolean. Required. |
Compute bill savings from caller interval generation and load under a time-of-use tariff with export credit, net metering or no export value. Price $0.03 USDC. POST /api/v1/solar-design/tariff-savings. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| intervalHours | number | no | intervalHours, number. Required. |
| loadKwh | array | yes | loadKwh, array. Required. |
| generationKwh | array | yes | generationKwh, array. Required. |
| importPrice | array | yes | importPrice, array. Required. |
| exportMode | string | no | exportMode, string, one of export_rate, net_metering_kwh, none. Required. |
| exportPrice | number | no | exportPrice, number, from 0 to any. Required. |
| fixedCharges | number | no | fixedCharges, number, from 0 to any. Required. |
| demandCharge | no | demandCharge, value. Optional. | |
| billingPeriods | array | no | billingPeriods, array. Optional. |
Compute simple payback, NPV, IRR and LCOE from capex, incentives, year-1 energy, degradation, O&M and price escalation. Price $0.03 USDC. POST /api/v1/solar-design/financial-payback. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| capex | number | yes | capex, number. Required. |
| upfrontIncentives | number | no | upfrontIncentives, number, from 0 to any. Required. |
| year1EnergyKwh | number | yes | year1EnergyKwh, number. Required. |
| degradation | number | no | degradation, number, from -0.5 to 1. Required. |
| energyValuePerKwh | number | yes | energyValuePerKwh, number. Required. |
| energyEscalation | number | no | energyEscalation, number, from -0.5 to 1. Required. |
| omPerYear | number | no | omPerYear, number, from 0 to any. Required. |
| omEscalation | number | no | omEscalation, number, from -0.5 to 1. Required. |
| years | integer | yes | years, integer, from 1 to 50. Required. |
| discountRate | number | yes | discountRate, number, from -0.5 to 1. Required. |
Maximise the number of modules on a roof-face polygon with caller setbacks, orientation, gaps and obstruction polygons. Price $0.04 USDC. POST /api/v1/solar-design/module-layout-fit. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| roof | array | yes | roof, array. Required. |
| setback | number | yes | setback, number, from 0 to any. Required. |
| module | object | yes | module, object. Required. |
| gap | number | no | gap, number, from 0 to any. Required. |
| orientations | array | no | orientations, array. Required. |
| obstructions | array | no | obstructions, array. Required. |
| gridOffsets | integer | no | gridOffsets, integer, from 1 to 25. Required. |
Compute PV circuit maximum current and minimum conductor ampacity using NEC 690.8 125% factors for the selected code edition. Price $0.02 USDC. POST /api/v1/solar-design/nec-690-current. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| edition | string | no | edition, string, one of 2017, 2020, 2023. Required. |
| moduleIsc | number | yes | moduleIsc, number. Required. |
| parallelStrings | integer | no | parallelStrings, integer, from any to 9007199254740991. Required. |
| continuousFactor | number | no | continuousFactor, number. Required. |
Normalise and compare module datasheet values for efficiency, W/m², temperature-adjusted power, price per watt and warranty retention. Price $0.02 USDC. POST /api/v1/solar-design/module-spec-compare. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| modules | array | yes | modules, array. Required. |
| referenceCellTemp | number | no | referenceCellTemp, number. Required. |
Parse PVsyst PAN (module) and OND (inverter) text files into nested raw JSON and a normalised datasheet object. Price $0.02 USDC. POST /api/v1/solar-design/pan-ond-parse. An unpaid call returns the x402 payment terms and does not run.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| fileType | string | yes | fileType, string, one of pan, ond. Required. |
| content | string | yes | content, string, length 1 to 524288. Required. |
- Every tool — any call limit is its publisher’s, not ours
- No card, and mcprush charges nothing for it
- Runs at its publisher’s own address — this marketplace is not in the path
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install BRAINIAC Solar PV Design Calculations or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
| Term | Level | What it prices | Points |
|---|---|---|---|
| capability-exposure | minimal | capability blast radius (minimal) — client exposure if the model is manipulated | −0 |
| coverage-honesty | manifest | inspection depth (manifest) — how much of the target the scan could see | −4 |
What the scan could actually read
A grade is only as meaningful as its coverage, so the scanner publishes its own depth before it publishes its result.
The scan read each tool’s name, description, input schema and annotations exactly as the server listed them the last time it answered us; no code was reviewed. We ask the server again about once a month, and a list that changed is graded again.
The implementation source was not read — this reflects the declared tool metadata only.
Capability — what it could do if the model were manipulated
Tags derived from each tool’s schema and the implementation, not from what the tool calls itself. minimal is the level these add up to.
| Tool | Capability tags | Why the tag was assigned |
|---|---|---|
| solar-design_string-sizing | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_dc-ac-ratio-check | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_poa-irradiance-transpose | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_energy-yield-estimate | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_row-spacing | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_horizon-shading-loss | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_system-loss-stack | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_battery-backup-sizing | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_tariff-savings | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_financial-payback | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_module-layout-fit | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_nec-690-current | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_module-spec-compare | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
| solar-design_pan-ond-parse | untrusted-input | untrusted-input: declares openWorldHint: true (interacts with entities outside the server) |
Toxic-flow graph
The lethal trifecta, checked as a graph rather than as a checklist: untrusted input, a sensitive source and an external sink have to meet before there is a path worth worrying about.
The public result for this release does not print the flow graph, so there is nothing to show here. That is not the same as "no paths were found": what the scan did read is above, under coverage.
Supply chain and provenance
This is the first scan of this surface here, so there is nothing yet to compare it against.
Every result on this tab comes from one deterministic pass over the published package — offline, rule by rule, and auditable line by line above. Same methodology version, same bytes, same score.
Release history
This is an address its publisher runs: which release it serves is theirs to choose, so there is nothing here to pin. The history below is for reading; the current release on file is 1.0.1.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish BRAINIAC Solar PV Design Calculations can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.