Blender integration through the Model Context Protocol
RackArchitect is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Hosted Remote MCP & 3D/2D Rack-as-Code planner, 5-stage validator, CAD SVG/BOM & STL generator.
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user --transport http rackarchitect-mcp https://mcp.rackarchitect.dev/mcp
# 2 — ask your agent for something these tools do
# search_catalog, get_device_blueprint, define_custom_blueprint and 9 more
RackArchitect costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. Nothing here runs on your machine and nothing runs on ours: this server answers at its publisher’s own address, and what you install is the connection straight to it.
This is a public server: it answers at its publisher’s own address and this marketplace is not in the path. Claude Code registers it in one command; --scope user makes it available in every project. The transport below is http, as the publisher's own manifest declares it.
claude mcp add --scope user --transport http rackarchitect-mcp https://mcp.rackarchitect.dev/mcpReconnect, or start a new session, and the tools appear in the model’s tool list.
One config entry pointing straight at the publisher’s own address — this marketplace is not in the path, and nothing from this listing executes on your machine.
12 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Search and filter the local hardware catalog to discover compatible rackmount devices, modular carriers, and sub-modules before mounting. All supplied filters combine with logical AND: 'form_factor' and its alias 'mount_type' accept width shorthands '10inch', '19inch', and '6inch' that match both direct rackmount gear and modular carriers, 'accepted_slot_type' matches both carrier bays and compati
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | Optional case-insensitive substring filter matching slug, manufacturer, or model name (omit to match all). |
| form_factor | string | no | Primary rack width or mounting form-factor filter (shorthands "10inch", "19inch", and "6inch" match both direct rackmount equipment and modular carriers of that width). |
| mount_type | string | no | Optional alias for form_factor to filter by physical mounting style ("rackmount-10", "rackmount-19", "rackmount-6", "sub-module", or "shelf-standing"); combined with logical AND if both are provided. |
| category | string | no | Functional hardware category filter (e.g., "switch", "router", "ups", "pdu", "patch-panel", "modular-carrier", "mini-pc", "sbc"). |
| max_depth_mm | number | no | Maximum allowed chassis depth in millimeters (inclusive upper bound). |
| min_poe_budget_watts | number | no | Minimum required PSE PoE output power budget in watts (inclusive lower bound). |
| accepted_slot_type | string | no | Sub-module slot compatibility token matching either a sub-module slot_compatibility or a carrier slot accepted_slot_type (e.g., "mini-pc-1liter", "sbc-rpi5", "standard-keystone"). |
Retrieve the complete hardware specification, millimeter port coordinates, electrical and PoE ratings, and carrier slot geometry for a single catalog blueprint. The 'slug' parameter requires a case-sensitive exact match in lowercase kebab-case vendor-model-variant format against the built-in or session custom catalog; partial substrings or uppercase characters do not match. Returns the full bluepr
| Parameter | Type | Required | Notes |
|---|---|---|---|
| slug | string | yes | Exact lowercase kebab-case hardware catalog blueprint slug to retrieve (discoverable via search_catalog). |
Validate and register a custom hardware blueprint into the active catalog so unlisted equipment can be mounted. Pass the entire specification inside the top-level 'blueprint' object: 'blueprint.slug' must use lowercase kebab-case, ports may combine explicit 'ports[]' with repeating 'port_groups[]' macros whose coordinates fit strictly within 'blueprint.geometry' without overlapping, and 'slots[]'
| Parameter | Type | Required | Notes |
|---|---|---|---|
| blueprint | object | yes | Complete custom hardware blueprint specification; ports may be defined via explicit ports[], repeating port_groups[] macros, or both. |
Initialize a new rack project and destructively reset the active rack.yaml state to an empty enclosure with the specified width standard, U height, and rail depth. Overwrites the current enclosure and clears all mounted devices, child sub-modules, cables, and external endpoints, while pushing the previous project state onto the in-memory undo stack for recovery via undo_redo. 'project_name' sets t
| Parameter | Type | Required | Notes |
|---|---|---|---|
| project_name | string | no | Human-readable project name stored in rack.yaml. |
| standard | string | yes | Mechanical rack width standard ("19inch" = 482.6mm, "10inch" = 254.0mm, "6inch" = 152.4mm). |
| u_height | integer | yes | Total usable vertical rack height in Rack Units (1U = 44.45mm, 1..60U). |
| rail_depth_mm | number | yes | Front-to-rear mounting rail depth in millimeters along the Z-axis (max 2000mm). |
| enclosure_type | string | no | Enclosure door style ("open-frame", "closed-glass-front", or "closed-vented-front"). |
| front_door_clearance_mm | number | no | Available clearance in millimeters between front mounting rails (Z=0) and a closed front door. |
| rear_clearance_mm | number | no | Available clearance in millimeters behind the rear mounting rails (Z=rail_depth_mm) for power plugs and bending radii. |
Mount a new hardware device instance onto a rack unit or into a modular carrier bay in the active rack.yaml project and run 5-stage validation. 'instance_id' must be unique across both top-level devices and nested sub-modules, 'blueprint_slug' must reference an existing catalog or custom slug, and placement uses two mutually exclusive modes: 'u_position' with optional 'face' where the device's ful
| Parameter | Type | Required | Notes |
|---|---|---|---|
| instance_id | string | yes | Unique project-wide instance identifier for this mounted device (e.g., "ups-u1", "sw-core-01"). |
| blueprint_slug | string | yes | Catalog or custom hardware blueprint slug to instantiate. |
| hostname | string | no | Optional logical hostname or display label shown in elevations and schematics. |
| u_position | integer | no | 1-indexed lowest Rack Unit (U) when mounting directly onto the rack rails (mutually exclusive with parent_carrier_id/slot_id). |
| face | string | no | Target rack mounting face ("front" or "rear") for direct rackmount equipment. |
| parent_carrier_id | string | no | Mounted parent modular-carrier instance_id when mounting a sub-module (requires slot_id; mutually exclusive with u_position). |
| slot_id | string | no | Target bay slot_id inside parent_carrier_id when mounting a sub-module (e.g., "left-bay", "keystone-1"). |
Move, rename, or destructively remove an existing mounted device or child sub-module in the active rack, recalculate 3D cable splines, and re-run 5-stage validation. 'instance_id' resolves across top-level devices and carrier sub-modules, and required fields depend on 'action': 'move' updates 'u_position' and 'face' on rackmount gear or 'slot_id' and optional 'parent_carrier_id' across carriers fo
| Parameter | Type | Required | Notes |
|---|---|---|---|
| instance_id | string | yes | Existing mounted device or child sub-module instance_id to modify. |
| action | string | yes | Modification operation: "move" relocates a device, "rename" updates its hostname, and "remove" deletes the device instance. |
| u_position | integer | no | New 1-indexed U position when action is "move" on a direct rackmount device (takes precedence over new_u_position). |
| new_u_position | integer | no | Optional alias for u_position when action is "move". |
| face | string | no | New mounting face ("front" or "rear") when action is "move" on a rackmount device (takes precedence over new_face). |
| new_face | string | no | Optional alias for face when action is "move". |
| parent_carrier_id | string | no | Target parent carrier instance_id when action is "move" on a child sub-module. |
| slot_id | string | no | Target slot_id inside parent_carrier_id when action is "move" on a child sub-module. |
| hostname | string | no | New logical hostname when action is "rename" (takes precedence over new_hostname). |
| new_hostname | string | no | Optional alias for hostname when action is "rename". |
| remove_connected_cables | boolean | no | When action is "remove", whether to automatically disconnect all cables and external endpoints attached to the removed device (default: true). |
Connect or update a batch of up to 128 power and network cables between mounted device ports in the active rack, computing 3D Catmull-Rom splines, commercial length bins, and PoE or power budgets. Each entry in 'cables[]' upserts in place by 'cable_id' while leaving all other cables and mounted equipment untouched, pushes a recoverable undo snapshot, and persists rack.yaml atomically; port, speed,
| Parameter | Type | Required | Notes |
|---|---|---|---|
| cables | array | yes | Batch of one or more cable connections to upsert by cable_id, route in 3D, and validate (max 128 per call). |
Remove specific cables by identifier or strip all cables attached to a mounted device or modular carrier from the active rack, then re-evaluate PoE budgets and plug clearances. Supply a non-empty 'cable_ids' list, 'instance_id', or both to disconnect their union; 'instance_id' matches both 'from' and 'to' endpoints across a carrier and its child sub-modules while leaving external patch-panel drops
| Parameter | Type | Required | Notes |
|---|---|---|---|
| cable_ids | array | no | Specific cable_id values to disconnect (can be combined with instance_id; at least one of cable_ids or instance_id must be provided). |
| instance_id | string | no | Mounted device or modular-carrier instance_id whose attached cables (including child sub-module cables) should all be disconnected. |
Terminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel without consuming rack U slots, and optionally auto-create labeled Cat6A front patch cables to a mounted switch. 'groups[]' batch-generates drops first—with 'custom_labels[]' overriding numbered 'label_prefix' entries per index—followed by 'endpoints[]', allocating sequential free rear ports from 'sta
| Parameter | Type | Required | Notes |
|---|---|---|---|
| patch_panel_instance_id | string | yes | Mounted patch panel instance_id whose rear ports receive the incoming building cable drops. |
| start_port_number | integer | no | 1-indexed starting port number on the patch panel (defaults to next free rear port or 1). |
| entry_position | string | no | Rear building cable conduit entry point into the rack frame. |
| groups | array | no | Batch groups of external drops (e.g., 10x PoE cameras, 5x Wi-Fi APs, 5x room LAN outlets). |
| endpoints | array | no | Individual external building/room drops to terminate on the rear of the patch panel. |
| auto_connect_switch_instance_id | string | no | Optional switch instance_id to automatically patch from the front of the patch panel using labeled Cat6A cables. |
| auto_connect_switch_start_port | integer | no | 1-indexed starting Ethernet port number on auto_connect_switch_instance_id (e.g., 1 for eth1). |
| clear_existing | boolean | no | If true, destructively clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning. |
Inspect the active rack.yaml state and run all 5 deterministic validation stages covering mechanical bounds, 3D depth and plug clearances, PoE and power budgets, cable compatibility, and thermal limits. Takes no parameters, performs zero state or undo-stack mutations, and returns the ASCII front and rear elevation diagram, power utilization summary, and all diagnostic issues with remediation_sugge
No parameter schema on file.
Generate 2D elevation and wiring SVGs, a Markdown BOM, a binary 3D GLB scene, and parametric OpenSCAD or watertight STL 3D-print models for the active rack project. Omitting 'formats' exports all six types; 'carrier-scad' and 'carrier-stl' emit one file per mounted modular carrier, switch cradle, or printable cover panel and emit zero files when none are mounted, while 'output_dir' resolves relati
| Parameter | Type | Required | Notes |
|---|---|---|---|
| formats | array | no | Deliverable formats to generate and write to disk (defaults to all 6 formats; carrier-scad and carrier-stl emit files when modular carriers are mounted). |
| output_dir | string | no | Optional target filesystem directory for generated files in local stdio mode (defaults to the directory of the active rack.yaml file; ignored on hosted remote MCP servers where HTTPS download URLs are |
Traverse the per-project in-memory history ring buffer of up to 50 snapshots to revert the latest rack mutation or reapply a reverted mutation, updating rack.yaml atomically. Setting 'action' to 'undo' steps backward across rack-state mutations—excluding catalog-only define_custom_blueprint calls and read-only tools—and pushes the displaced state onto the redo stack, whereas 'redo' is available on
| Parameter | Type | Required | Notes |
|---|---|---|---|
| action | string | yes | History traversal direction: "undo" reverts the most recent state mutation, "redo" reapplies a reverted mutation. |
- Every tool — any call limit is its publisher’s, not ours
- No card, and mcprush charges nothing for it
- Runs at its publisher’s own address — this marketplace is not in the path
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install RackArchitect or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
| Term | Level | What it prices | Points |
|---|---|---|---|
| capability-exposure | moderate | capability blast radius (moderate) — client exposure if the model is manipulated | −3 |
| coverage-honesty | manifest | inspection depth (manifest) — how much of the target the scan could see | −4 |
What the scan could actually read
A grade is only as meaningful as its coverage, so the scanner publishes its own depth before it publishes its result.
The scan read each tool’s name, description, input schema and annotations exactly as the server listed them the last time it answered us; no code was reviewed. We ask the server again about once a month, and a list that changed is graded again.
The implementation source was not read — this reflects the declared tool metadata only.
Capability — what it could do if the model were manipulated
Tags derived from each tool’s schema and the implementation, not from what the tool calls itself. moderate is the level these add up to.
| Tool | Capability tags | Why the tag was assigned |
|---|---|---|
| search_catalog | no tags | |
| get_device_blueprint | no tags | |
| define_custom_blueprint | state-write | state-write: declares readOnlyHint: false |
| init_rack | state-write | state-write: declares readOnlyHint: false, destructiveHint: true |
| mount_equipment | state-write | state-write: declares readOnlyHint: false |
| modify_equipment | state-write | state-write: declares readOnlyHint: false, destructiveHint: true |
| connect_cables | state-write | state-write: declares readOnlyHint: false |
| disconnect_cables | state-write | state-write: declares readOnlyHint: false, destructiveHint: true |
| plan_external_endpoints | state-write | state-write: declares readOnlyHint: false, destructiveHint: true |
| validate_rack | no tags | |
| export_deliverables | untrusted-inputstate-write | untrusted-input: keyword "download"; state-write: declares readOnlyHint: false |
| undo_redo | state-write | state-write: declares readOnlyHint: false |
Toxic-flow graph
The lethal trifecta, checked as a graph rather than as a checklist: untrusted input, a sensitive source and an external sink have to meet before there is a path worth worrying about.
The public result for this release does not print the flow graph, so there is nothing to show here. That is not the same as "no paths were found": what the scan did read is above, under coverage.
Supply chain and provenance
This is the first scan of this surface here, so there is nothing yet to compare it against.
Every result on this tab comes from one deterministic pass over the published package — offline, rule by rule, and auditable line by line above. Same methodology version, same bytes, same score.
Release history
This is an address its publisher runs: which release it serves is theirs to choose, so there is nothing here to pin. The history below is for reading; the current release on file is 1.0.2.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish RackArchitect can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.