Configure and automate Home Assistant with Claude, ChatGPT, and other AI assistants.
Flow Pack is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Live heat pump planning checks and flood warnings, pipe and heat sizing, gas records for plumbers
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user --transport http flow-pack-mcp https://flow-pack.nerolabs.workers.dev/mcp
# 2 — ask your agent for something these tools do
# list_capabilities, size_pipe, size_heat_source and 5 more
Flow Pack costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. Nothing here runs on your machine and nothing runs on ours: this server answers at its publisher’s own address, and what you install is the connection straight to it.
This is a public server: it answers at its publisher’s own address and this marketplace is not in the path. Claude Code registers it in one command; --scope user makes it available in every project. The transport below is http, as the publisher's own manifest declares it.
claude mcp add --scope user --transport http flow-pack-mcp https://flow-pack.nerolabs.workers.dev/mcpReconnect, or start a new session, and the tools appear in the model’s tool list.
One config entry pointing straight at the publisher’s own address — this marketplace is not in the path, and nothing from this listing executes on your machine.
8 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.
No parameter schema on file.
Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metre and in total, and the pressure left at the outlet if you give the supply pressure. Gas: flow from the gross heat input of the appliances fed, pressure drop aga
| Parameter | Type | Required | Notes |
|---|---|---|---|
| medium | string | yes | — |
| run_length_m | number | yes | Measured pipe length, metres (from the meter for gas, from the stop tap or cylinder for water). |
| material | string | no | Water: copper (default), plastic, mdpe. Gas: copper (default), steel, csst. |
| pipe_size_mm | number | no | Check only this nominal size. |
| fittings | object | no | Count of fittings on the run. If left out, 30% is added to the length instead (or fittings_allowance_percent). |
| fittings_allowance_percent | number | no | Length added for fittings when they are not counted. Default 30. |
| service | string | no | Water only. Default cold. |
| outlets | array | no | Water only: outlets this pipe feeds. |
| simultaneous_outlets | number | no | Water only: how many outlets run at once. Default: square root of the number of outlets, rounded. |
| design_flow_l_s | number | no | Water only: design flow in litres a second, if known (overrides outlets). |
| supply_pressure_bar | number | no | Water only: working pressure at the start of the run (measured with water flowing). |
| min_pressure_at_outlet_bar | number | no | Water only: pressure needed at the end. Default 1.0 bar. |
| height_rise_m | number | no | Water only: height gained from start to outlet (negative if it falls). |
| water_temp_c | number | no | Water only. Default 10 cold, 60 hot. |
| max_velocity_m_s | number | no | Water only. Default 1.5. |
| gas | string | no | Gas only. Default natural_gas. |
| heat_input_kw_gross | number | no | Gas only: total gross heat input of every appliance this pipe feeds (data plate). |
| heat_input_kw_net | number | no | Gas only: if only the net figure is known. |
| gas_flow_m3_h | number | no | Gas only: gas flow, if already known. |
| allowed_drop_mbar | number | no | Gas only. Default 1 natural gas, 2.5 LPG. |
Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing also checks the hot water load (flow x temperature rise). Give each room's type, size and its walls, windows, roof and floor with U values, or construction presets f
| Parameter | Type | Required | Notes |
|---|---|---|---|
| heat_source | string | no | Default combi_boiler. |
| outside_design_temp_c | number | no | Local outside design temperature. Default -3. |
| rooms | array | yes | Up to 40 rooms. |
| margin_percent | number | no | Added to the heating load. Default 10 for boilers, 0 for heat pumps. |
| hot_water_flow_l_min | number | no | Combi: wanted hot water flow. Default 12. |
| hot_water_temp_rise_c | number | no | Combi: temperature rise. Default 35. |
| cylinder_litres | number | no | System or regular boiler: cylinder size. Default 150. |
| reheat_hours | number | no | Wanted reheat time. Default 1. |
| hot_water_priority | boolean | no | Default true (reheat load not added). |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not s |
For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls short, the water flow per radiator, indicative lengths by panel type, and with compare_flow_temp_c how much bigger radiators must be at a lower flow temperature (fo
| Parameter | Type | Required | Notes |
|---|---|---|---|
| flow_temp_c | number | no | Default 70. |
| return_temp_c | number | no | Default flow minus 10 (minus 5 at 55 C or lower). |
| rooms | array | yes | — |
| compare_flow_temp_c | number | no | — |
| compare_return_temp_c | number | no | — |
| radiator_exponent | number | no | Default 1.3. |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not s |
For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Water Fittings Regulations, regulation 5)? Returns, per job, who can do it, the self-certification route (competent person scheme within 30 days, or building contro
| Parameter | Type | Required | Notes |
|---|---|---|---|
| nation | string | no | Default england. |
| work | array | yes | One or more jobs. |
| water_approved_contractor | boolean | no | True if the installer is a water approved contractor (for example WaterSafe). |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not s |
Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate off the rated input, meter pressure out of range, an unsafe appliance marked safe, and the correct next due date (keeping the anniversary for checks done up to 2
| Parameter | Type | Required | Notes |
|---|---|---|---|
| record_type | string | yes | — |
| record | object | yes | The filled fields (see the description). |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not s |
For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an urgency value of routine, soon or emergency that matches Nero Work's three job speeds, raised for water near electrics, a bulging ceiling, a vulnerable person in the cold, or water that
| Parameter | Type | Required | Notes |
|---|---|---|---|
| situation | string | yes | — |
| nation | string | no | Changes the gas emergency number for Northern Ireland. |
| vulnerable_people | boolean | no | Elderly, very young, disabled or medically vulnerable person in the home. |
| outside_temp_c | number | no | — |
| water_near_electrics | boolean | no | — |
| ceiling_bulging | boolean | no | — |
| water_stopped | boolean | no | Has turning off the stop tap or valve stopped the water? |
| pipe_split | boolean | no | — |
| other_heating_available | boolean | no | — |
| only_toilet | boolean | no | — |
| sewage_inside | boolean | no | — |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not s |
Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable nero_trade_ref computed from the scheme registration (licence_body gas_safe plus the Gas Safe registration number) or the company number. The same shape and reference as Spark Pack, so one business keeps one ref
| Parameter | Type | Required | Notes |
|---|---|---|---|
| trade | object | yes | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not s |
- Every tool — any call limit is its publisher’s, not ours
- No card, and mcprush charges nothing for it
- Runs at its publisher’s own address — this marketplace is not in the path
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install Flow Pack or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
| Term | Level | What it prices | Points |
|---|---|---|---|
| capability-exposure | minimal | capability blast radius (minimal) — client exposure if the model is manipulated | −0 |
| coverage-honesty | manifest | inspection depth (manifest) — how much of the target the scan could see | −4 |
What the scan could actually read
A grade is only as meaningful as its coverage, so the scanner publishes its own depth before it publishes its result.
The scan read each tool’s name, description, input schema and annotations exactly as the server listed them the last time it answered us; no code was reviewed. We ask the server again about once a month, and a list that changed is graded again.
The implementation source was not read — this reflects the declared tool metadata only.
Capability — what it could do if the model were manipulated
Tags derived from each tool’s schema and the implementation, not from what the tool calls itself. minimal is the level these add up to.
| Tool | Capability tags | Why the tag was assigned |
|---|---|---|
| list_capabilities | no tags | |
| size_pipe | no tags | |
| size_heat_source | no tags | |
| size_radiators | no tags | |
| check_notifiable_work | no tags | |
| check_gas_record | no tags | |
| emergency_triage | no tags | |
| trade_profile | no tags |
Toxic-flow graph
The lethal trifecta, checked as a graph rather than as a checklist: untrusted input, a sensitive source and an external sink have to meet before there is a path worth worrying about.
The public result for this release does not print the flow graph, so there is nothing to show here. That is not the same as "no paths were found": what the scan did read is above, under coverage.
Supply chain and provenance
This is the first scan of this surface here, so there is nothing yet to compare it against.
Every result on this tab comes from one deterministic pass over the published package — offline, rule by rule, and auditable line by line above. Same methodology version, same bytes, same score.
Release history
This is an address its publisher runs: which release it serves is theirs to choose, so there is nothing here to pin. The history below is for reading; the current release on file is 1.2.0.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish Flow Pack can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.