Blender integration through the Model Context Protocol
EasyEDA is installed from its publisher's own source and answers where it runs, so this marketplace is not in the path of a single call. There is no address here to send one to, and a panel that pretended otherwise would be showing you an answer we made up. Install it and call it from your own client — the Installation tab has the entry for each one.
What it does
Read and draw EasyEDA Pro schematics and PCBs through a bridge extension, with guarded edits.
Quickstart
# 1 — add it to Claude Code
claude mcp add --scope user zzvllvzz-easyeda-mcp '--' npx -y easyeda-pro-mcp
# 2 — ask your agent for something these tools do
# eda_status, eda_exec, eda_call and 9 more
EasyEDA costs nothing on mcprush: there is no plan to choose here, no cap to set and nothing mcprush can bill you for.
Collected from a public index. Nobody has claimed this account, so nothing here was written by its author — claim it if it is yours.
Where are you running it?
Every route below installs the same thing and ends at the same approval screen. This one runs on your machine: your client starts EasyEDA as a process under your own user, with your files and your network, so the tool surface below is what it can do to your computer rather than to a server somewhere else. Its scan result is on the Security tab — read the surface before you approve it.
This is a public server: you run it yourself and this marketplace is not in the path. You need Node.js — the current LTS (24) is the safe choice; npx comes with it. Claude Code registers it in one command; --scope user makes it available in every project. The '--' is in quotes so that PowerShell passes it on.
claude mcp add --scope user zzvllvzz-easyeda-mcp '--' npx -y easyeda-pro-mcpReconnect, or start a new session, and the tools appear in the model’s tool list.
Nothing is required, but it can take EASYEDA_MCP_PORT (Local port of the bridge extension. Defaults to 49731; the extension has to use the same port.), EASYEDA_MCP_OUT (Folder for exported files. Defaults to ~/.easyeda-mcp/out.), EASYEDA_MCP_ORIGINS (Extra browser origins allowed to connect, comma separated.) if you want to set them.
One config entry your client uses to start the process locally. A local server runs with your file system and your network, which is why it is priced without metering.
12 tools, with what each one reads, writes and reaches shown before you agree — the same list on every route above. Read the tool surface.
Tool surface
What the model actually sees. Descriptions are diffed on every release — see version history.
Read from its source code. A server that builds its tool list when it starts can list more tools than this.
Check the bridge: is EasyEDA Pro connected, which editor/extension version, and what project/document/page is active.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| waitMs | integer | no | How long to wait for EasyEDA to connect before giving up (default 8000). |
Run JavaScript inside EasyEDA Pro and get the returned value. The code is the body of an async function with eda (the EasyEDA extension API), h (helpers), args (your JSON), console (captured) and store (object that persists between calls). Use return for the result. Do many operations…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| code | string | yes | Body of an async function. Example: const w = await h.wires('GND'); return w.length; |
| args | no | Any JSON value, available in the code as args. | |
| timeoutMs | integer | no | Time limit in ms (default 30000). Code that times out keeps running in EasyEDA. |
| maxChars | integer | no | Inline result limit (default …); larger results are saved to a file and previewed. |
| saveTo | string | no | Absolute path: save the result (or the returned File) there instead of returning it inline. |
Call one EasyEDA API method by path, e.g. method 'sch_PrimitiveWire.getAll' with args ['GND']. Shortcut for simple reads and single writes; for anything with loops use eda_exec. Look up signatures with eda_api.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| method | string | yes | Path under eda, e.g. dmt_Schematic.getCurrentSchematicPageInfo |
| args | array | no | Positional arguments (default none). |
| timeoutMs | integer | no | — |
| maxChars | integer | no | — |
| saveTo | string | no | — |
Look up the EasyEDA Pro extension API (offline, from the official typings; doc comments are in Chinese). query: keyword search over method names and docs. name: full listing of a class/eda object (sch_PrimitiveWire), an interface, enum or type, or one method with remarks and example…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | Keywords, e.g. 'netlist' or 'pin modify'. |
| name | string | no | Class, eda property, interface, enum, type, or Class.method. |
| limit | integer | no | Max search results (default 20). |
| examples | boolean | no | With name of a class: include remarks and examples for every method (long). |
Read the active schematic page compactly. what: 'summary' (counts, designators, net names of wires), 'parts' (components with pin coordinates), 'wires', 'snapshot' (parts+flags+wires), 'nets' (whole-schematic netlist {net: pins}), 'net' (one net by name or by pin like 'U1.3', needs net), 'check'…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| what | string | no | — |
| des | array | no | Only these designators (parts). |
| net | string | no | Net name (wires, net) or a pin like U1.3 (net). |
| region | array | no | [x1,y1,x2,y2] |
| pins | boolean | no | Include pins for parts/snapshot (default true). |
| size | array | no | what:'free': [width, height] of the block to fit. |
| count | integer | no | what:'free': how many places to return (default 1). |
| maxChars | integer | no | — |
| saveTo | string | no | — |
Apply a list of drawing operations to the active schematic page as ONE change: afterwards either all of it is on the page or none of it. The netlist is read before and after (guard): nets with different names that became one net are a short, and a short takes the whole change back, as does a…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| ops | array | yes | — |
| trial | boolean | no | Do it, report what it does to the nets, then take everything back. |
| expect | object | no | {NET: ['U1.3','R2.1']}: these nets must consist of exactly these pins afterwards, else the change is taken back. A key starting with '?' checks an unnamed net. |
| allowShorts | no | true, or a list of net names that may be joined on purpose. | |
| rollback | boolean | no | Default true: take everything back on a failed op, a short or a failed expect. false keeps what was done. |
| guard | boolean | no | Default true. false skips the two netlists (faster, no short detection). |
| keepGoing | boolean | no | Continue after a failed op (turns rollback off unless it is set). |
| verbose | boolean | no | Return an entry for every op, not only parts and problems. |
| timeoutMs | integer | no | Default 180000. |
Export from the active schematic to a file and return its path: pdf (look at the real drawing; open the path with the Read tool), png, svg, netlist (PADS text), bom (csv), view (image of what the canvas currently shows; may be stale).
| Parameter | Type | Required | Notes |
|---|---|---|---|
| format | string | yes | — |
| path | string | no | Absolute file path or directory. Default: ~/.easyeda-mcp/out/ |
| options | object | no | Passed to h.exportFile: {name?, params?, resolution?, type?, tabId?, object?, objectParams?}. pdf exports the current page by default; object: 'Current Schematic' or 'All Schematic' for more. |
| timeoutMs | integer | no | Default 90000. |
Search the EasyEDA/LCSC device library by words ('100nF 0402 X7R', 'STM32F103C8T6') or look up LCSC numbers. Returns name, LCSC number, footprint, JLCPCB class (Basic/Extended) and the uuid pair that {op:'part', device:{uuid, libraryUuid}} takes.
| Parameter | Type | Required | Notes |
|---|---|---|---|
| query | string | no | Words to search for. |
| lcsc | array | no | Instead of query: LCSC numbers like C25804. |
| limit | integer | no | Default 10. |
| page | integer | no | — |
| datasheet | boolean | no | Include datasheet links. |
Read the active PCB (open one with pcb_do action:'open'). what: 'info' (layers, rule set, outline size, counts), 'parts' (components; pads:true adds pad coordinates and nets), 'tracks', 'vias', 'shapes' (polylines, pours, regions, fills, texts), 'nets' (pads, track length, tracks and vias per net;…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| what | string | no | — |
| des | array | no | parts: only these designators. |
| pads | boolean | no | parts: include pad coordinates. |
| net | string | no | tracks, vias, nets: only this net. |
| layer | no | tracks: layer number or name (top, bottom, topsilk, outline, inner1...). | |
| unit | string | no | — |
| max | integer | no | drc: how many errors to list (default 60). |
| maxChars | integer | no | — |
| saveTo | string | no | — |
Apply a list of operations to the active PCB as ONE change. The design rule check runs before and after (guard): a new error other than a not-yet-routed connection (clearance, short, overlap with a keep-out) takes the whole change back, as does a failed op; pours are refilled before judging.…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| ops | array | yes | — |
| unit | string | no | — |
| trial | boolean | no | Do it, report the rule check, then take everything back. |
| rollback | boolean | no | Default true: take everything back on a failed op or a new rule error. |
| allowErrors | boolean | no | Keep the change even if it adds rule errors (they are still reported). |
| guard | boolean | no | Default true. false skips the rule checks. |
| rebuild | boolean | no | Default true: refill pours before the rule check. |
| keepGoing | boolean | no | — |
| verbose | boolean | no | — |
| timeoutMs | integer | no | Default 300000. |
Whole-board actions. action: 'open' (open a PCB of the project by name or uuid, the first one by default), 'import' (bring the schematic's changes onto the board; lists the changes and applies them, apply:false only lists), 'rebuild' (refill all pours), 'autoroute' (EasyEDA's own router; props…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| action | string | yes | — |
| name | string | no | open: PCB name or uuid. |
| apply | boolean | no | import: default true. |
| props | object | no | autoroute: IPCB_AutoRoutingProps. |
| net | string | no | unroute: only this net. |
| timeoutMs | integer | no | Default 300000. |
Export from the active PCB to a file and return its path: gerber (zip for fabrication), pnp (pick and place csv), bom, netlist, step, obj (3D), dxf, dsn (for external routers), ipc356, ipc2581, odb, testpoints, info, altium, pads, view (picture of what the canvas shows). Nothing is ordered:…
| Parameter | Type | Required | Notes |
|---|---|---|---|
| format | string | yes | — |
| path | string | no | Absolute file path or directory. Default: ~/.easyeda-mcp/out/ |
| options | object | no | Passed to h.pcb.exportFile: {name?, type?, unit?, layers?, objects?, ...}. |
| timeoutMs | integer | no | Default 180000. |
- Every tool, no call limit
- No card, and mcprush charges nothing for it
- Source published under MIT
- Runs on your machine — nothing of it reaches our gateway
- Nothing to cap, because mcprush bills nothing
What counts against your monthly calls
| Tool | Unit | Calls used | Out of the allowance |
|---|
Nothing here is billable: mcprush charges nothing to install EasyEDA or to call it, at any volume.
Two independent axes, because powerful and malicious are different questions. The grade is threat only. The capability level is blast radius, and it is never a penalty on the grade — it is priced as one subtract-only term in the score, where you can see it.
| Term | Level | What it prices | Points |
|---|---|---|---|
| capability-exposure | high | capability blast radius (high) — client exposure if the model is manipulated | −6 |
| verification-discount | repo | publisher verification (public source) — no provenance, but the source is public and inspectable | −1 |
| coverage-honesty | source | inspection depth (source) — how much of the target the scan could see | −0 |
What the scan could actually read
A grade is only as meaningful as its coverage, so the scanner publishes its own depth before it publishes its result.
Tools were statically extracted from the published source (12 recovered), not enumerated from a running server. Tool-poisoning, Unicode-smuggling, capability and toxic-flow analysis ran on this inferred surface, but a mis-parsed registration could be missed or mis-attributed, so tool-derived findings are capped below “confirmed”. To grade the real runtime surface, scan the running server: --command "npx -y <package>".
Capability — what it could do if the model were manipulated
Tags derived from each tool’s schema and the implementation, not from what the tool calls itself. high is the level these add up to.
| Tool | Capability tags | Why the tag was assigned |
|---|---|---|
| eda_status | no tags | |
| eda_exec | code-exec | code-exec: keyword "exec" in tool name |
| eda_call | no tags | |
| eda_api | no tags | |
| sch_read | no tags | |
| sch_draw | no tags | |
| sch_export | no tags | |
| lib_search | no tags | |
| pcb_read | no tags | |
| pcb_draw | no tags | |
| pcb_do | no tags | |
| pcb_export | no tags |
Toxic-flow graph
The lethal trifecta, checked as a graph rather than as a checklist: untrusted input, a sensitive source and an external sink have to meet before there is a path worth worrying about.
The public result for this release does not print the flow graph, so there is nothing to show here. That is not the same as "no paths were found": what the scan did read is above, under coverage.
Supply chain and provenance
This is the first scan of this surface here, so there is nothing yet to compare it against.
Every result on this tab comes from one deterministic pass over the published package — offline, rule by rule, and auditable line by line above. Same methodology version, same bytes, same score.
Release history
Always latest — the install command names no version, so it installs the newest release when it runs; the current release on file is 0.1.0. Pin a release below and the command asks for exactly that one.
No release note was published with this version.
One review per account, from a signed-in account that does not publish this listing. Nothing else is asked — you can say what you think before you install it. Publishers can reply once per review, and a review can be edited or deleted by whoever wrote it.
Any signed-in account that does not publish EasyEDA can review it, once — before installing it or after. A review from an account that has installed it is marked as one.
Nobody has reviewed this listing. The rating on the card is the mean of the reviews written here and nothing else, so there is no rating until somebody writes the first — which takes a signed-in account that does not publish it, and nothing else.